CoatMentorCoating standards, explained

Standard · Concrete

ASTM F1869

Moisture vapor emission rate of a concrete slab with anhydrous calcium chloride.

Publisher
ASTM International
Area
Concrete

ASTM F1869 measures how much moisture vapor leaves a bare concrete floor. A weighed dish of anhydrous calcium chloride sits under a sealed plastic dome on the concrete; the gain in weight gives the moisture vapor emission rate (MVER).

The procedure

The traps

The dish stays on for 60 to 72 hours; the result is only expressed per 24 hours. F1869 is a test method with no pass mark of its own: the limit comes from the coating or flooring maker or the specification. The test does not suit lightweight-aggregate or gypsum concrete, or concrete under a coating.

4 practice items in the members area mention ASTM F1869 (CIP 2: 3 · FROSIO written: 1).

Related

Try it in an exam-style question. The free readiness check shows the question style, explains every answer and gives you a dated study plan.

Take the free readiness checkSee the tracks

About this page

This page describes the subject of ASTM F1869 in our own words; it does not reproduce the standard. For the full text, buy the current edition from ASTM International. Checked on 2026-10-14; errors go in the corrections log. CoatMentor is an independent study aid. It is not affiliated with ISO, AMPP, SSPC, NACE International, ASTM or FROSIO.